<?xml version="1.0"?>
<?xml-stylesheet type="text/css" href="http://wiki01.acd.net//wiki/skins/common/feed.css?303"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
		<id>http://wiki01.acd.net//wiki/index.php?action=history&amp;feed=atom&amp;title=Datacenter_collocation_specifications</id>
		<title>Datacenter collocation specifications - Revision history</title>
		<link rel="self" type="application/atom+xml" href="http://wiki01.acd.net//wiki/index.php?action=history&amp;feed=atom&amp;title=Datacenter_collocation_specifications"/>
		<link rel="alternate" type="text/html" href="http://wiki01.acd.net//wiki/index.php?title=Datacenter_collocation_specifications&amp;action=history"/>
		<updated>2026-06-12T17:00:32Z</updated>
		<subtitle>Revision history for this page on the wiki</subtitle>
		<generator>MediaWiki 1.19.23</generator>

	<entry>
		<id>http://wiki01.acd.net//wiki/index.php?title=Datacenter_collocation_specifications&amp;diff=1134&amp;oldid=prev</id>
		<title>Schoen.kevin at 15:42, 3 June 2015</title>
		<link rel="alternate" type="text/html" href="http://wiki01.acd.net//wiki/index.php?title=Datacenter_collocation_specifications&amp;diff=1134&amp;oldid=prev"/>
				<updated>2015-06-03T15:42:46Z</updated>
		
		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table class='diff diff-contentalign-left'&gt;
				&lt;col class='diff-marker' /&gt;
				&lt;col class='diff-content' /&gt;
				&lt;col class='diff-marker' /&gt;
				&lt;col class='diff-content' /&gt;
			&lt;tr valign='top'&gt;
			&lt;td colspan='2' style=&quot;background-color: white; color:black;&quot;&gt;← Older revision&lt;/td&gt;
			&lt;td colspan='2' style=&quot;background-color: white; color:black;&quot;&gt;Revision as of 15:42, 3 June 2015&lt;/td&gt;
			&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 3:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 3:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;ACD will only collocate in &amp;quot;Carrier Neutral&amp;quot; sites where we have access and the ability to freely connect to others, and are able to bring in fiber optic cables into the location without restriction. &amp;#160;&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;ACD will only collocate in &amp;quot;Carrier Neutral&amp;quot; sites where we have access and the ability to freely connect to others, and are able to bring in fiber optic cables into the location without restriction. &amp;#160;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;−&lt;/td&gt;&lt;td style=&quot;background: #ffa; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;*&lt;del class=&quot;diffchange diffchange-inline&quot;&gt;Stage &lt;/del&gt;1: Customer aggregation locations. &amp;#160;&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;background: #cfc; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;*&lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;Series &lt;/ins&gt;1: Customer aggregation locations. &amp;#160;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;background: #cfc; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;&lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;*Series 1a: Typically are locations that we are installing equipment for Fiber to the Home. The equipment in these locations is &amp;quot;hardend&amp;quot; gear with a wide tempurature range. Often in the field we are deploying road side pedestals and pole mounted cabinets. These cabinets have passive cooling, and are outfitted with battery systems, these locations are not required to be generator powered. Typically these locations are homed to Series 1b locations All ACD equipment runs on -48VDC. &lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;background: #cfc; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;&lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;*Series 1b: Typically these are locations that we are installing equipment to aggregate Series 1b locations (i.e fiber to the home cabinets). The locations may also be used to aggregate residential customers. These locations are usually road side huts or central office locations. We &lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;*Stage 2: Hosting location.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;*Stage 2: Hosting location.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;background: #cfc; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;color: red; font-weight: bold; text-decoration: none;&quot;&gt;**These are locations where there are multiple users that have web hosting applications or server platforms, and these users need access to ACD backbone Internet or point-to-point connections. &lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;*Stage 3: Carrier-to-Carrier Datacenters. &amp;#160;&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;*Stage 3: Carrier-to-Carrier Datacenters. &amp;#160;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;background: #cfc; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;color: red; font-weight: bold; text-decoration: none;&quot;&gt;**These locations have have multiple carriers, or are generally consider carrier hotels.&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;Access Requirements:&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;Access Requirements:&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 11:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 15:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;* ACD does not collocate in sites that use metal keys or other restrictions, or where we have to call someone before we have access.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;* ACD does not collocate in sites that use metal keys or other restrictions, or where we have to call someone before we have access.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;* ACD does not collocate in shared use sites MTU/MDU sites that do not have key card access. &amp;#160;&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;* ACD does not collocate in shared use sites MTU/MDU sites that do not have key card access. &amp;#160;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;−&lt;/td&gt;&lt;td style=&quot;background: #ffa; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;&amp;#160;&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;background: #cfc; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;&lt;ins class=&quot;diffchange diffchange-inline&quot;&gt; &lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;Cabinets:&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;Cabinets:&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>Schoen.kevin</name></author>	</entry>

	<entry>
		<id>http://wiki01.acd.net//wiki/index.php?title=Datacenter_collocation_specifications&amp;diff=1133&amp;oldid=prev</id>
		<title>Schoen.kevin at 03:48, 3 June 2015</title>
		<link rel="alternate" type="text/html" href="http://wiki01.acd.net//wiki/index.php?title=Datacenter_collocation_specifications&amp;diff=1133&amp;oldid=prev"/>
				<updated>2015-06-03T03:48:19Z</updated>
		
		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table class='diff diff-contentalign-left'&gt;
				&lt;col class='diff-marker' /&gt;
				&lt;col class='diff-content' /&gt;
				&lt;col class='diff-marker' /&gt;
				&lt;col class='diff-content' /&gt;
			&lt;tr valign='top'&gt;
			&lt;td colspan='2' style=&quot;background-color: white; color:black;&quot;&gt;← Older revision&lt;/td&gt;
			&lt;td colspan='2' style=&quot;background-color: white; color:black;&quot;&gt;Revision as of 03:48, 3 June 2015&lt;/td&gt;
			&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 3:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 3:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;ACD will only collocate in &amp;quot;Carrier Neutral&amp;quot; sites where we have access and the ability to freely connect to others, and are able to bring in fiber optic cables into the location without restriction. &amp;#160;&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;ACD will only collocate in &amp;quot;Carrier Neutral&amp;quot; sites where we have access and the ability to freely connect to others, and are able to bring in fiber optic cables into the location without restriction. &amp;#160;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;−&lt;/td&gt;&lt;td style=&quot;background: #ffa; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;&lt;del class=&quot;diffchange diffchange-inline&quot;&gt;ACD does not place aggregation equipment at customer sites in exchange for services. &lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;background: #cfc; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;&lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;*&lt;/ins&gt;Stage 1: Customer aggregation locations. &amp;#160;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;−&lt;/td&gt;&lt;td style=&quot;background: #ffa; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;&amp;#160;&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;background: #cfc; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;&lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;*&lt;/ins&gt;Stage 2: Hosting location.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;−&lt;/td&gt;&lt;td style=&quot;background: #ffa; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;Stage 1: Customer aggregation locations. &amp;#160;&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;background: #cfc; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;&lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;*&lt;/ins&gt;Stage 3: Carrier-to-Carrier Datacenters. &amp;#160;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;−&lt;/td&gt;&lt;td style=&quot;background: #ffa; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;Stage 2: Hosting location.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;background: #cfc; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;−&lt;/td&gt;&lt;td style=&quot;background: #ffa; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;Stage 3: Carrier-to-Carrier Datacenters. &amp;#160;&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;background: #cfc; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;Access Requirements:&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;Access Requirements:&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>Schoen.kevin</name></author>	</entry>

	<entry>
		<id>http://wiki01.acd.net//wiki/index.php?title=Datacenter_collocation_specifications&amp;diff=1132&amp;oldid=prev</id>
		<title>Schoen.kevin at 03:47, 3 June 2015</title>
		<link rel="alternate" type="text/html" href="http://wiki01.acd.net//wiki/index.php?title=Datacenter_collocation_specifications&amp;diff=1132&amp;oldid=prev"/>
				<updated>2015-06-03T03:47:01Z</updated>
		
		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table class='diff diff-contentalign-left'&gt;
				&lt;col class='diff-marker' /&gt;
				&lt;col class='diff-content' /&gt;
				&lt;col class='diff-marker' /&gt;
				&lt;col class='diff-content' /&gt;
			&lt;tr valign='top'&gt;
			&lt;td colspan='2' style=&quot;background-color: white; color:black;&quot;&gt;← Older revision&lt;/td&gt;
			&lt;td colspan='2' style=&quot;background-color: white; color:black;&quot;&gt;Revision as of 03:47, 3 June 2015&lt;/td&gt;
			&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 1:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 1:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;ACD collocates gear within datacenters or hosting sites for the purposes of a) distributing bandwidth to other end users b) providing redundancy to our network c) providing bandwidth within the datacenters.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;ACD collocates gear within datacenters or hosting sites for the purposes of a) distributing bandwidth to other end users b) providing redundancy to our network c) providing bandwidth within the datacenters.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;−&lt;/td&gt;&lt;td style=&quot;background: #ffa; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;ACD will only collocate in &amp;quot;Carrier Neutral&amp;quot; sites where we have access and the ability to freely connect to others, and are able to bring in fiber optic cables &lt;del class=&quot;diffchange diffchange-inline&quot;&gt;to &lt;/del&gt;the &lt;del class=&quot;diffchange diffchange-inline&quot;&gt;locations&lt;/del&gt;.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;background: #cfc; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;ACD will only collocate in &amp;quot;Carrier Neutral&amp;quot; sites where we have access and the ability to freely connect to others, and are able to bring in fiber optic cables &lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;into &lt;/ins&gt;the &lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;location without restriction&lt;/ins&gt;. &amp;#160;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;−&lt;/td&gt;&lt;td style=&quot;background: #ffa; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;ACD does not place aggregation equipment at customer sites in exchange for services. &lt;del class=&quot;diffchange diffchange-inline&quot;&gt;ACD does not place equipment in &lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;background: #cfc; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;ACD does not place aggregation equipment at customer sites in exchange for services. &amp;#160;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;Stage 1: Customer aggregation locations. &amp;#160;&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;Stage 1: Customer aggregation locations. &amp;#160;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 38:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 38:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;**208/220/240 V &amp;#160;&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;**208/220/240 V &amp;#160;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;* 30 amp each, dual feed, separately fused.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;* 30 amp each, dual feed, separately fused.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;background: #cfc; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;color: red; font-weight: bold; text-decoration: none;&quot;&gt;&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;background: #cfc; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;color: red; font-weight: bold; text-decoration: none;&quot;&gt;Battery feeds and Generator systems will be evaluated on a case-by-case basis.&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>Schoen.kevin</name></author>	</entry>

	<entry>
		<id>http://wiki01.acd.net//wiki/index.php?title=Datacenter_collocation_specifications&amp;diff=1131&amp;oldid=prev</id>
		<title>Schoen.kevin: Created page with &quot;ACD collocates gear within datacenters or hosting sites for the purposes of a) distributing bandwidth to other end users b) providing redundancy to our network c) providing ba...&quot;</title>
		<link rel="alternate" type="text/html" href="http://wiki01.acd.net//wiki/index.php?title=Datacenter_collocation_specifications&amp;diff=1131&amp;oldid=prev"/>
				<updated>2015-06-03T03:45:36Z</updated>
		
		<summary type="html">&lt;p&gt;Created page with &amp;quot;ACD collocates gear within datacenters or hosting sites for the purposes of a) distributing bandwidth to other end users b) providing redundancy to our network c) providing ba...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;ACD collocates gear within datacenters or hosting sites for the purposes of a) distributing bandwidth to other end users b) providing redundancy to our network c) providing bandwidth within the datacenters.&lt;br /&gt;
&lt;br /&gt;
ACD will only collocate in &amp;quot;Carrier Neutral&amp;quot; sites where we have access and the ability to freely connect to others, and are able to bring in fiber optic cables to the locations.&lt;br /&gt;
&lt;br /&gt;
ACD does not place aggregation equipment at customer sites in exchange for services. ACD does not place equipment in &lt;br /&gt;
&lt;br /&gt;
Stage 1: Customer aggregation locations. &lt;br /&gt;
Stage 2: Hosting location.&lt;br /&gt;
Stage 3: Carrier-to-Carrier Datacenters. &lt;br /&gt;
&lt;br /&gt;
Access Requirements:&lt;br /&gt;
* 24*7*365 access via swipe cards/key cards only. &lt;br /&gt;
* ACD does not collocate in sites that use metal keys or other restrictions, or where we have to call someone before we have access.&lt;br /&gt;
* ACD does not collocate in shared use sites MTU/MDU sites that do not have key card access. &lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Cabinets:&lt;br /&gt;
* 19&amp;quot; Rackmount, 4 post.&lt;br /&gt;
* 32&amp;quot; depth.&lt;br /&gt;
* Standard 7ft or 42in Rack Unit.&lt;br /&gt;
* We do not share rack space. &lt;br /&gt;
&lt;br /&gt;
Open Frame Racks:&lt;br /&gt;
* 19&amp;quot; or 23&amp;quot; Racks&lt;br /&gt;
* ability to have 32&amp;quot; in depth.&lt;br /&gt;
* We do not share rack space.&lt;br /&gt;
* Space should be caged or limited access, i.e. carrier meet-me area. &lt;br /&gt;
&lt;br /&gt;
Building Entrance:&lt;br /&gt;
* 1&amp;quot; 1/4 HDPE conduit or larger.&lt;br /&gt;
* qty 2 minimum.&lt;br /&gt;
* ability to add more conduits. &lt;br /&gt;
&lt;br /&gt;
Power: Either AC or DC, please specify availability.&lt;br /&gt;
* DC is preferred for Carrier-to-Carrier locations.&lt;br /&gt;
**-48vdc, 50 amps per feed, dual feed required. &lt;br /&gt;
* AC power&lt;br /&gt;
**208/220/240 V &lt;br /&gt;
* 30 amp each, dual feed, separately fused.&lt;/div&gt;</summary>